Recommended for financeable resource assessment campaigns, the Hukseflux LP02 is a solar radiation sensor that is compliant with second class criteria from the ISO 9060 standard.
#6889
This thermopile-based sensor measures global horizontal irradiance and has a spectrally flat response across the full solar spectrum. The LP02 generates a small voltage signal that is proportional to the solar radiation flux, expressed in W/m2.
The LP02 is compatible with the SymphoniePLUS®3 Data Logger and SymphoniePRO® Data Logger when equipped with a Symphonie® SCM Card (SCM #6646, used with SymphoniePLUS3 or older) or Pro Signal Conditioning Module (P-SCM #9128, used with SymphoniePRO).
This kit includes a calibration certificate and 5 m (16.4') cable.
Hukseflux LP02 Pyranometer (#6889) | |
---|---|
Description | |
Sensor type | Thermopile solar radiation sensor; ISO 9060 ‘Second Class’ compliant |
Applications |
|
Sensor range | 0 W/m2 to 2000 W/m2 |
Spectral range | 305 nm to 2800 nm |
Instrument compatibility |
|
Output signal | |
Signal type | Microvolt proportional to total solar radiation |
Transfer function | Included on calibration certificate; for use with RNRG Symphonie see application note "Using Thermopile Pyranometers on Symphonie Loggers" |
Accuracy | Second Class per ISO 9060 |
Calibration |
Calibration sheet included with each sensor defines output in microvolts per Watt/square meter; traceable to World Radiometric Reference (WRR) Calibration uncertainty < 1.8% (k=2) as specified by Hukseflux |
Output signal range | -0.1 mV to + 50 mV |
Drift | Less than 1% per year |
Power requirements | |
Power Required | Zero (passive sensor) |
Installation | |
Mounting | Mounts to tower with RNRG tower top mounting platform (9104) or side mounting boom (6772) (plane of array capable) |
Tools required |
|
Environmental | |
Operating temperature range | -40 °C to 80 °C (-40 °F to 176 °F) |
Operating humidity range | 0 to 100% |
Physical | |
Connections |
Bare wire leads from cable connect directly to logger see also logger user's manual for wiring diagram |
Cable length | 5 m (16.4 feet) |
Weight | 0.30 kg (0.66 lbs) |
Dimensions | 85 mm X 60 mm (3.3 inches X 2.4 inches) |
Materials | |
Cable | Shielded 2 conductor |
Detector | Thermopile |
Enclosure | IP67 weatherproof anodized aluminum enclosure and stainless steel hardware |
For Software downloads and details click here